Battery Testers
Neware, China
Neware is one of the market leaders in battery quality check, battery performance
test, battery material research and battery mass production.
Product Offering:
-
CT-4000 Series: Suitable for Coin Cells, Super Capacitors,
Cylindrical Cells, Pouch Cells, Three Electrode System Testing.
-
CE-6000 Series: Multiple-Scenario Battery Testing System.
-
CT/CTE-8000 Series: Coupled with working condition simulation can be used for Power Battery and Energy Storage System.
-
CT-9000 Series: Mainly used for Coin Cells, 3C digital Battery and Material Investigation.
-
All-in-One Testing System: Conducting efficient testing and research on battery temperature
performance for Coin Cells.
-
4 Temperature zone All-in-One Testing System: Meet the Material Manufacturers, Universities and Research Institutes of multiple temperature testing requirements for Coin Cells.
-
200L Constant Temperature Test Chamber: Suitable for the temperature performance test of various batteries such as Coin, Pouch, Cylindrical and Prismatic Cells.
-
High and Low Temperature Test Chamber: Suitable for the high and low temperature performance test of various batteries, such as Coin, Pouch, Cylindrical and Prismatic Cells.
CT-4008Tn-5V10mA | CT-4008Tn-5V20mA | CT-4008Tn-5V50mA |
---|---|---|
CT-4008Tn-5V50mA | CT-4008T n-5V1A | CT-4008-10V10A |
CT-4008Tn-5V12A | CT-4008-10V3A | CT-4008-10V6A |
CT-4008-10V10A | CT-4008-10V10A | CT-4008-10V50A |
CT-4008-10V30A U | CT-4004-10V100A | CT-4004-10V200A |
Battery Testing Equipment
Coin Cell Battery Testing System
CT-4008Tn-5V10/20/50mA-164
-
Accuracy: 0.05%FS;
-
Data Acquisition Frequency :10Hz/100Hz;
-
3 Range;
-
dQ/dV;
-
Application: For Coin Cell
CT-4000Q-100mA-124
-
Current&Voltage: 5V100mA
-
Accuracy: 0.01%FS
-
Data Acquisition Frequency: 10Hz/100Hz
-
4 Range
-
dQ/dV
-
Application: For Coin Cel
CT-4008Tn-5V10mA(Supercap)
-
Current&Voltage: 5V10mA
-
Accuracy: 0.05%FS
-
Data Acquisition Frequency: 10Hz/100Hz
-
3 Range
-
dQ/dV
-
Application: Supercap Testing
3C Digital Battery Testing System
CT-4008Tn-5V10/20/50mA-164
-
Accuracy: 0.05%FS;
-
Data Acquisition Frequency :10Hz/100Hz;
-
3 Range;
-
dQ/dV;
-
Application: For Coin Cell
CT-4000Q-100mA-124
-
Current&Voltage: 5V100mA
-
Accuracy: 0.01%FS
-
Data Acquisition Frequency: 10Hz/100Hz
-
4 Range
-
dQ/dV
-
Application: For Coin Cel
CT-4008Tn-5V10mA(Supercap)
-
Current&Voltage: 5V10mA
-
Accuracy: 0.05%FS
-
Data Acquisition Frequency: 10Hz/100Hz
-
3 Range
-
dQ/dV
-
Application: Supercap Testing
Battery Testing System for Power Cell
CTE-4008D-5V30A-(NTA)
-
Current&Voltage: 5V30A
-
Total Number of Channels: 8
-
Accuracy: 0.05%FS
-
Data Acquisition Frequency :10Hz
-
3 Range
-
Application: Regenerative Power Cell Testing
CT-4008-5V30A-(NTA)
● Current&Voltage: 5V30A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Power Cell Testing
CTE-4032D-5V30A
-
Current&Voltage: 5V30A;
-
Total Number of Channels: 32;
-
Accuracy: 0.05%FS;
-
Data Acquisition Frequency :10Hz;
-
3 Range;
-
Application: Regenerative Power Cell Testing
CT-4008-5V60A-NTA
● Current&Voltage: 5V60A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4064D-5V30A
● Current&Voltage: 5V30A;
● Total Number of Channels: 64;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4064D-5V30A
● Current&Voltage: 5V30A;
● Total Number of Channels: 64;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V100A-NTA
● Current&Voltage: 5V100A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V120A-NTA
● Current&Voltage: 5V120A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4032-5V100A-NTA
● Current&Voltage: 5V100A;
● Total Number of Channels: 32;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CT-4008-5V120A-NTA
● Current&Voltage: 5V120A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4048-5V120A
● Current&Voltage: 5V120A;
● Total Number of Channels: 8;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing
CTE-4016-5V200A
● Current&Voltage: 5V200A;
● Total Number of Channels: 16;
● Accuracy: 0.05%FS;
● Data Acquisition Frequency :10Hz;
● 3 Range;
● Application: Regenerative Power Cell Testing